Checks each magazine fiducial in the I/E station

Performs Get/Put tests on all the I/E station cells

Scanner fiducial test

The scanner fiducial test performs the following tasks:

Scans and checks each magazine fiducial

Scans and checks each drive sled fiducial

Tests the calibration sensor

Calibrates and checks repeatability, up to three times for marginal and failed calibration
targets

Tower assembly test

The tower assembly test performs the following tasks:

Checks for tower horizontal and vertical alignment

Checks tower rotation backlash and drift

Checks tower alignment

Initiating verification tests

This section provides instructions for running the installation verification test, partial tests, FRU
operational tests, and custom tests. The test results appear after the tests complete.

To stop a test, disable the robotics by pressing the Robotics Enable button on the OCP or by clicking
Stop on the Verification Tests window. Control will be returned to you as soon as the current
command is completed.

The different reports (Library Report, Drive Report, and Blade Report) are generated and viewed
in the Reports area of the Verification Tests window.

If a typical user logs on while an administrator is logged on and running a verification test, testing
will continue unaffected. Only one administrator can be logged on at any given time.

Running the installation verification test

When the installation verification test is running, no one else can log on to the library. The message
Verification Test is Running

appears in the Activity area of the main LMC display.

To run the installation verification test:

1.

Log on as an administrator.

2.

Ensure that you are viewing the physical library. From the View menu or in the Managed
Views area of the LMC, select the name of the physical library.

3.

Select Tools

→Library Diagnostics→Verification Tests.

4.

On Verification Tests, click Install from the Select Test drop-down list.

5.

Click Start.

6.

If prompted to take the library offline, click Yes.