Care and cleaning, Lift-off oven door, Probe – GE ZGP304LRSS User Manual

Page 31

Advertising
background image

Care and Cleaning

Professional All-Gas Range

7KHGRRULVYHU\KHDY\%HFDUHIXOZKHQUHPRYLQJ
DQGOLIWLQJWKHGRRU

Do not lift the door by the handle.

7RUHPRYHWKHGRRU

1. Fully open the door.

2. Pull the hinge locks down toward the door

frame, to the unlocked position. A tool, such as
a small flat-blade screwdriver, may be required.

3. Firmly grasp both sides of the door DWWKHWRS.
4. Close door to the door removal position,

(approximately 15 degrees from closed) and
lift it up and out until the hinge arm is clear
of the slot.

7RUHSODFHWKHGRRU

1. Firmly grasp both sides of the door DWWKHWRS.
2. With the door at the same angle as the

removal position, seat the indentation of the
hinge arm into the bottom edge of the hinge
slot. The notch in the hinge arm must be fully
seated into the bottom of the slot.

3. Fully open the door. If the door will not fully

open, the indentation is not seated correctly in the
bottom edge of the slot.

4. Push the hinge locks up against the front frame

of the oven cavity, to the locked position.

5. Close the oven door.

Lift-off

oven door

Hinge arm

Indentation

Bottom

edge

of slot

Removal position

Hinge lock

Slot

Pull hinge locks down to unlock

Hinge

lock

Hinge arm

Push hinge locks up to lock

Probe

Allow the temperature probe to cool before
cleaning.

The probe should be cleaned with soap and
water by hand.

Do not immerse the temperature probe in water.

Do not store the temperature probe in the oven.

Do not clean the temperature probe in the
self-cleaning oven.

31

Replacement

position

Advertising