Table 4-1 remote command summary (cont) – Boonton 4530 Peak Power Meter User Manual User Manual
Page 131
4-57
Boonton Electronics
Chapter 4
4530 Series RF Power Meter
Remote Operation
CALibration[1 | 2]:{INTernal | EXTernal}:ZERO[?]
Performs sensor zero offset null adjustment,[return err flag]
CALibration[1 | 2]:{INTernal | EXTernal}:FIXEDcal[?]
Performs single-point sensor gain calibration, [return err flag]
CALibration[1 | 2]:{INTernal | EXTernal}:AUTOcal[?]
Performs multi-point sensor gain “step” calibration, [return err flag]
CALibration[1 | 2]:USER:FREQcal[?]
Performs single-point snsr gain cal with user ref signal, [return err flag]
DISPlay:%SPAN <n>
set/return statistical mode horizontal trace span in percent
DISPlay:%OFST <n>
set/return statistical mode horizontal trace offset in percent
DISPlay:TSPAN <n>
set/return horizontal time span <n> = [mode dependent]
DISPlay:DATA?
return 3200 chars+terminator which encode pixels of the display
DISPlay:TEXT[1 | 2]:BARgraph <asc>
set/return bargraph visibility, <asc> = OFF, ON
DISPlay:TEXT[1 | 2]:RESolution <n>
set/return main readout resolution in decimal places, <n> = 1, 2, 3
DISPlay:GRPH[1 | 2] <n>
action: select single channel graph display, <n>=1, 2, 3 is display page
DISPlay:GRPHB <n>
action: select dual channel graph display, <n>=1, 2, 3 is display page
DISPlay:TXT[1 | 2] <n>
action: select single channel text display, <n>=1, 2, 3 is display page
DISPlay:TXTB <n>
action: select dual channel text display, <n>=1, 2, 3 is display page
DISPlay:TRACe[1 | 2]:LOGSPAN <n>
set/return vertical span in dB
DISPlay:TRACe[1 | 2]:LINSPAN <n>
set/return vertical span in Watts / Volts
DISPlay:TRACe[1 | 2]:PCTSPAN <n>
set/return vertical span in Percent
DISPlay:TRACe[1 | 2]:LOGCNTR <n>
set/return vertical center in dBm / dBr
DISPlay:TRACe[1 | 2]:LINCNTR <n>
set/return vertical center in Watts / Volts
DISPlay:TRACe[1 | 2]:PCTCNTR <n>
set/return vertical center in Percent.
FETCh[1 | 2]:CW:POWer?
return current average reading in power units
FETCh[1 | 2]:CW:VOLTage?
return current average reading in voltage units
FETCh[1 | 2]:MARKer[1 | 2]:POWer?
return current reading at the specified marker
FETCh[1 | 2]:ARRay:MARKer:POWer?
return current readings at both markers
FETCh[1 | 2]:ARRay:MARKer:PERcent?
return current statistical percent at both markers
FETCh[1 | 2]:ARRay:CW:POWer?
return array of current power readings
FETCh[1 | 2]:ARRay:CW:VOLTage?
return array of current voltage readings
FETCh[1 | 2]:ARRay:PULse:POWer?
return array of current marker measurements
FETCh[1 | 2]:ARRay:AMEAsure:TIMe?
return array of current automatic pulse timing measurements
FETCh[1 | 2]:ARRay:AMEAsure:POWer?
return array of current automatic pulse power measurements
INITiate:CONTinuous <asc>
set/return state of mode which triggers meas cycles continuously
INITiate[:IMMediate[:ALL]]
set mode which starts a measurement cycle when trigger event occurs
MARKer:MODe <asc>
set/return global marker mode, <asc> = OFF, VERT, HORZ
MARKer:POSition[1 | 2]:POWer <n>
set/return marker power, <n> = -99.99 to +99.99 dBm
MARKer:POSition[1 | 2]:TIMe <n>
set/return marker time relative to the trigger, <n> =(+/- SPAN/2+Tdly)
MARKer:POSition[1 | 2]:PERcent <n>
set/return marker statistical percent, (vertical marker) <n> = 0 to 100 %
MEASure[1 | 2]:POWer?
return average power measurement using default configuration
MEASure[1 | 2]:VOLTage?
return average voltage measurement using default configuration
Table 4-1 Remote Command Summary (Cont)