Table 3-5. main menu summary - (cont) – Boonton 4530 Peak Power Meter User Manual User Manual

Page 67

Advertising
background image

3-45

Boonton Electronics

Chapter 3

4530 Series RF Power Meter

Operation

FrDepOfst . . . . . . . . . . . . . . . . . . . . Freq Dependent Offset Submenu

Ofst Src . . . . . . . . . . . . . . . . . . . . . Select Offset Table <None, TableA, TableB>
Modify-A . . . . . . . . . . . . . . . . . . . . . View/edit Freq Dep Offset Table A
Modify-B . . . . . . . . . . . . . . . . . . . . . View/edit Freq Dep Offset Table B

Snsr Data . . . . . . . . . . . . . . . . . . . . Sensor Data Submenu

SensrInfo . . . . . . . . . . . . . . . . . . . . View general sensor information
FastTable . . . . . . . . . . . . . . . . . . . . View high-bw calfactor table (Peak Sensors only)
SlowTable . . . . . . . . . . . . . . . . . . . . View low-bw calfactor table (Peak Sensors only)
FreqTable . . . . . . . . . . . . . . . . . . . . View frequency calfactor table (CW Sensors only)
GainConst . . . . . . . . . . . . . . . . . . . View linearity calibration table (CW Sensors only)
TempComp . . . . . . . . . . . . . . . . . . . Select temperature compensation mode <On, Off>

Load Ref . . . . . . . . . . . . . . . . . . . . . Load Reference level from currently measured power
Ref Off

. . . . . . . . . . . . . . . . . . . . . Disable Reference

Enter Ref . . . . . . . . . . . . . . . . . . . . Enter Reference level from keyboard

Markers

. . . . . . . . . . . . . . . . . . . . . Marker Control Menu

Mrkr Mode . . . . . . . . . . . . . . . . . . . Select Marker Mode <Off, Vertical, Horizontal>
Mrk1 Pos . . . . . . . . . . . . . . . . . . . . Set Marker 1 position
Mrk2 Pos . . . . . . . . . . . . . . . . . . . . Set Marker 2 position

Trig/Time

. . . . . . . . . . . . . . . . . . . . . Trigger / Time Configuration Menu

Time Span . . . . . . . . . . . . . . . . . . . Select measurement time span
Trig Pos. . . . . . . . . . . . . . . . . . . . . . Select trigger position (Pulse Mode only)
TrigDelay . . . . . . . . . . . . . . . . . . . . Set trigger delay time (Pulse Mode only)
TrigLevel . . . . . . . . . . . . . . . . . . . . . Set trigger level (Pulse Mode only)
TrigSlope . . . . . . . . . . . . . . . . . . . . Select trigger slope (Pulse Mode only)
HoldOff

. . . . . . . . . . . . . . . . . . . . . Set trigger holdoff time (Pulse Mode only)

Trig Srce . . . . . . . . . . . . . . . . . . . . . Select trigger source
Trig Mode . . . . . . . . . . . . . . . . . . . . Select trigger mode <Auto, Norm, Pk-to-Pk>

Statisticl

. . . . . . . . . . . . . . . . . . . . . Statistical Mode Configuration Menu

Horz Span . . . . . . . . . . . . . . . . . . . Select horizontal axis sensitivity
% Offset . . . . . . . . . . . . . . . . . . . . . Set horizontal axis display center
Stat Mode . . . . . . . . . . . . . . . . . . . . Select mode <CDF, 1-CDF, Histogram>
TrmCount . . . . . . . . . . . . . . . . . . . . Set number of samples to acquire
TrmAction . . . . . . . . . . . . . . . . . . . . Select action at TermCount <stop, restart, decimate>

Calibratr

. . . . . . . . . . . . . . . . . . . . . Calibration Control Menu

[Int | Ext] Signal . . . . . . . . . . . . . . . Select output signal <Off, On, (Int-Pulse, Ext-Pulse)>
Level

. . . . . . . . . . . . . . . . . . . . . Set calibrator output level

PlsPeriod . . . . . . . . . . . . . . . . . . . . Select Pulse Period (external calibrator only)
DutyCycle . . . . . . . . . . . . . . . . . . . . Select Pulse Duty Cycle (external calibrator only)
[Int | Ext] Status . . . . . . . . . . . . . . . View status of internal/external calibrator
Select [Int | Ext] . . . . . . . . . . . . . . . Select internal/external calibrator

Save/Recl

. . . . . . . . . . . . . . . . . . . . . Instrument Save/Recall Menu

SetupSave . . . . . . . . . . . . . . . . . . . Save current setup to memory[1,2,3,4]
SetupRecl . . . . . . . . . . . . . . . . . . . . Recall current setup from memory[1,2,3,4]

Table 3-5. Main Menu Summary - (Cont)