Apdu exchange command – MagTek IntelliStripe65 99875161 User Manual

Page 102

Advertising
background image

IntelliStripe 65 Command Reference


96

A 4 byte ATR is returned when the power up command is successful. Many I

2

C

cards do not

deliver an ATR on power up, but some do. If the value FFFFFFFFH is returned, the card did not
deliver an ATR. The presence or absence of an ATR may not

positively identify the card in the

reader. If the ATR is different from FFFFFFFFH it probably does identify the card, see
specifications for the various cards to determine which ATR identifies which card. If
FFFFFFFFH is returned, the card may be an I

2

C

card that does not deliver an ATR. The only

way to be sure is to send a Read Binary to retrieve known data from a card you are familiar with.

APDU Exchange Command

The APDU Exchange Command is used to control logical operations of the card between Power
Up and Power Down. The APDU is issued as with Microprocessor cards. The Result Codes are
the same as for Microprocessor cards. When the Result Code indicates an Error or Warning, the
Primary Status of the CondRpt Property will never be 0x03.

Two SW1/SW2 Status Codes may apply to any APDU:

SW1/SW2

Meaning

6E00

CLA Not Supported

6D00

INS Not Supported

9000

Normal completion, no errors

Advertising