Notify indicator change 0 to 1 property – MagTek IntelliStripe65 99875161 User Manual

Page 59

Advertising
background image

Section 7. Transport Application

53

Example Get Property Response:

Field

MTYP

APPL

CMND

RC

PTYP

PID

Byte

1

2

3

4

5

6

Value (Hex)

40

82

00

00

01

00

Field

PVAL

Byte

7 - 10

Value (Hex)

07 00 00 00 (Card is present, seated and latched)

NOTIFY INDICATOR CHANGE 0 TO 1 PROPERTY

Property ID: 01 (Hex)
Property Type: Dword
Power Up/Reset Value: 0
Get/Set/Save support: All
Description:
This property is used control notification messages sent in response to a transport indicator
changing from a 0 to a 1 state. If the bit corresponding to an indicator is set then, a notification
message will be sent from the device to the host in response to that indicator changing from a 0
to a 1 state. The notification message will have the same syntax as the get property command
response of the indicator property. The only difference is that the message header will contain a
notification message type instead of a response message type. If more than one indicator
changes state at the same time, only one notification message will be sent that contains the state
of all the indicators.

Values:
The bits are identified by numbering the least significant bit 0 and the most significant bit 31.

Bits

Indicator

Description

0

Card Present

If set to 1 a notification message will be sent in response to a
0 to 1 transition of the card present indicator. If cleared to 0,
no notification will be sent.

1

Card Seated

If set to 1 a notification message will be sent in response to a
0 to 1 transition of the card seated indicator. If cleared to 0,
no notification will be sent.

2 – 6

RFU

Reserved for future use

7

*MagnePrint Noise If set to 1 a notification message will be sent in response to a

0 to 1 transition of the MagnePrint™ noise indicator. If
cleared to 0, no notification will be sent.

8-31

RFU

Reserved for future use

* Available only on units with MagnePrint feature