Rf off command, Sending oti module transparent commands – MagTek IntelliStripe65 99875161 User Manual
Page 85
![background image](/manuals/413731/85/background.png)
Section 10. OTI SCI 1000 Contactless Smart Card Application
79
Example Response:
Field
MTYP
APPL
CMND
RC
Byte
1
2
3
4
Value (Hex)
40
0E
84
00
RF OFF COMMAND
Command ID: 85 (Hex)
Description:
This command is used to turn the RF field OFF. When this command is accepted by the reader,
the automatic control of the RF will also be disabled
Request Message Data: None
Response Message Data: None
Response Message Result Codes:
Success = 00 (Hex)
The command completed successfully.
Example Request:
Field
MTYP
APPL
CMND
RC
Byte
1
2
3
4
Value (Hex)
00
0E
85
00
Example Response:
Field
MTYP
APPL
CMND
RC
Byte
1
2
3
4
Value (Hex)
40
0E
85
00
SENDING OTI MODULE TRANSPARENT COMMANDS
Command ID: 81 (Hex)
Description:
This command is used to send additional commands to the OTI module through the IS65
interface.
Request Message Data: None
Response Message Data: None
Response Message Result Codes:
Success = 00 (Hex)
The command completed successfully.