Get magneprint data command – MagTek IntelliStripe65 99875161 User Manual

Page 27

Advertising
background image

Section 4. Magnetic Stripe Application

21

Response Message Result Codes:

Success = 00 (Hex)

The command completed successfully.

Bad Parameter = 06 (Hex)

The command failed due to a bad parameter in the request message data field

Example Request:

Field

MTYP

APPL

CMND

RC

TRACK

Byte

1

2

3

4

5

Value (Hex)

00

01

82

00

02

Example Response:

Field

MTYP

APPL

CMND

RC

TRACK

DCD STAT

Byte

1

2

3

4

5

6

Value (Hex)

40

01

82

00

02

00

Field

ENCD TYP

TK DATA

Byte

7

8 - 41

Value (Hex)

00

Track2


GET MAGNEPRINT DATA COMMAND

Command ID: 86 (Hex)
Description:
This command is used to get MagnePrint™ information for the most recently read card.

Note 1: This command available only on units with MagnePrint feature.

Note2: MagnePrint™ data obtained from a read-on-insert swipe (see MSR Direction Property in
the Transport section) will not correlate as well as data obtained from a read on withdrawal.
We recommend setting the MSR Direction Property to withdrawal when using the MagnePrint™
data.

Request Message Data: None

Advertising