IntelliStripe 65 Command Reference

42

Example Response:

Field

MTYP

APPL

CMND

RC

DATA

Byte

1

2

3

4

5-8

Value (Hex)

40

02

80

00

3B 60 00 00


POWER DOWN COMMAND

Command ID: 81 (Hex)
Description:
This command is used to power down a smart card in the currently selected connector.

Request Message Data: None
Response Message Data: None
Response Message Result Codes

Code Meaning
00

Success.


Example Request:

Field

MTYP

APPL

CMND

RC

Byte

1

2

3

4

Value (Hex)

00

02

81

00


Example Response:

Field

MTYP

APPL

CMND

RC

Byte

1

2

3

4

Value (Hex)

40

02

81

00


T=0 ERROR / WARNING CONDITION TEMPLATES

Byte

Bit

Meaning

0

0

Timeout On Receive. This condition indicates a receive timeout.

0

1

Unrecoverable Receive Error. This condition indicates a receive error
that could not be corrected by the permitted number of parity
correction retries.

0

2

Invalid Procedure Byte received from card.

0

3

Unrecoverable Transmit Error. This condition indicates a transmit
error that could not be corrected by the permitted number of parity
correction retries.

0

4-7 Reserved for Future Use

1-3

All

Reserved for Future Use