IntelliStripe 65 Command Reference

70

Example Set Property Response:

Field

MTYP

APPL

CMND

RC

Byte

1

2

3

4

Value (Hex)

40

08

01

00


MCP AUTO BAUD ENABLE PROPERTY

Property ID: 05 (Hex)
Property Type: Boolean
Power Up/Reset Value: 01 (hex) (True)
Get/Set/Save support: All
Description:
This property enables or disables MCP auto baud synchronization. This feature is enabled if this
property is set to 1 (true) or disabled if this property is set to 0 (false). When this property is
disabled, the device will no longer require the host to perform the auto baud synchronization
sequence. Instead, the device will use the fixed baud rate specified by the host communication
applications fixed baud rate property. After changing this property, the property will also need
to be saved in non-volatile memory (Save property command) and the device will need to be
power cycled or reset before the change will take affect.

Example Set Property Request:

Field

MTYP

APPL

CMND

RC

PTYP

PID

Byte

1

2

3

4

5

6

Value (Hex)

00

08

01

00

03

05

Field

PVAL

Byte

7

Value (Hex)

01 (true)

Example Set Property Response: