IntelliStripe 65 Command Reference

26

Notification message will be sent later when the command has completed. The Notification
message is identical in every way except for its Command Type to the Response message that
would have been sent if the request had completed in a timely manner.

Example Request/Response/Notification Sequence

Request message (Power Up Command):

Field

MTYP

APPL

CMND

RC

Byte

1

2

3

4

Value (Hex)

00

02

80

80


Response message (RC = 80 means Request Initiated, Notification to follow):

Field

MTYP

APPL

CMND

RC

Byte

1

2

3

4

Value (Hex)

40

02

80

80


Notification message (Card Powered Up OK, Data is ATR):

Field

MTYP

APPL

CMND

RC

PVAL

Byte

1

2

3

4

5-8

Value (Hex)

80

02

80

00

3B 60 00 0A