IntelliStripe 65 Command Reference
26
Notification message will be sent later when the command has completed. The Notification
message is identical in every way except for its Command Type to the Response message that
would have been sent if the request had completed in a timely manner.
Example Request/Response/Notification Sequence
Request message (Power Up Command):
Field
MTYP
APPL
CMND
RC
Byte
1
2
3
4
Value (Hex)
00
02
80
80
Response message (RC = 80 means Request Initiated, Notification to follow):
Field
MTYP
APPL
CMND
RC
Byte
1
2
3
4
Value (Hex)
40
02
80
80
Notification message (Card Powered Up OK, Data is ATR):
Field
MTYP
APPL
CMND
RC
PVAL
Byte
1
2
3
4
5-8
Value (Hex)
80
02
80
00
3B 60 00 0A