IntelliStripe 65 Command Reference

56

Caution:

Be careful when setting the MSR Arm State to Armed to Read Multiple times while
the MSR Direction is set to both or non-directional. The reason for this is the
user is in control of how fast the card is swiped. If the time period between an
insert and a withdrawal is too short, a new read may occur before the magnetic
stripe data can be processed and sent to the host. The same situation could occur
if the time period between a withdrawal and an insert is too short. This time
period depends on how soon the host requests data after a card is read. If the
read data is being sent to the host using a notification message then this time
period is 500ms maximum.


Example Set Property Request:

Field

MTYP

APPL

CMND

RC

PTYP

PID

Byte

1

2

3

4

5

6

Value (Hex)

00

82

01

00

01

03

Field

PVAL

Byte

7 - 10

Value (Hex)

01 00 00 00 (Armed to Read Once)

Example Set Property Response:

Field

MTYP

APPL

CMND

RC

Byte

1

2

3

4

Value (Hex)

40

82

01

00


MSR DIRECTION PROPERTY

Property ID: 04 (Hex)
Property Type: Dword
Power Up/Reset Value: 2 (Withdrawal)
Get/Set/Save support: All
Description:
This property is used to control the magnetic stripe read direction. This state must be set
properly in order to read magnetic stripe cards. This property should be used with the MSR Arm
State property.