Select connector command – MagTek IntelliStripe65 99875161 User Manual

Page 54

Advertising
background image

IntelliStripe 65 Command Reference

48

Example Request:

Field

MTYP

APPL

CMND

RC

DATA

Byte

1

2

3

4

5-11

Value (Hex)

00

02

85

00

00 A4 02 0C 02 00 01


Example Response:

Field

MTYP

APPL

CMND

RC

DATA

Byte

1

2

3

4

5-6

Value (Hex)

40

02

85

00

90 00


SELECT CONNECTOR COMMAND

Command ID: 86 (Hex)
Description:
The IFD supports up to 8 connectors numbered 0-7. Connector 0 is the User Connector, and is
used by default when the system starts. Connectors 1-7 may be used for Secure Access Modules
(SAMs) as part of application infrastructure.

This command allows the application to select the connector to be used in commands that follow.
The connector assignment stays in effect until it is changed by another Select Connector
Command or the device is power cycled.

Request Message Data:

Byte Field

Description

1

Connector Number

The number, in Hex, to be selected


Response Message Data:
None
Response Message Result Codes

Code Meaning

00

Success


Example Request:

Field

MTYP

APPL

CMND

RC

DATA

Byte

1

2

3

4

5

Value (Hex)

00

02

86

00

02

Example Response:

Field

MTYP

APPL

CMND

RC

Byte

1

2

3

4

Value (Hex)

40

02

86

00