Tone sequence 2 property – MagTek IntelliStripe65 99875161 User Manual

Page 66

Advertising
background image

IntelliStripe 65 Command Reference

60

Byte Usage

1

TIB0, designates tone
0 = Silent
1 = Low
2 = Medium
3 = High
Other values may not result in a tone

2

TIB1, duration of tone in units of 10 milliseconds (e.g. 3 = 30
milliseconds). Setting this byte to zero terminates the Tone Sequence
without processing further entries


Example Get Property Request:

Field

MTYP

APPL

CMND

RC

PTYP

PID

Byte

1

2

3

4

5

6

Value (Hex)

00

07

00

00

04

01


Example Get Property Response:

Field

MTYP

APPL

CMND

RC

PTYP

PID

Byte

1

2

3

4

5

6

Value (Hex)

40

07

00

00

04

01

PVAL

7-26

01 10 02 20 03 30 00 00 00 00 00 00 00 00 00 00 00 00 00 00


TONE SEQUENCE 2 PROPERTY

Property ID: 02 (Hex)
Property Type: Binary
Length: 20
Power Up/Reset Value: 0330 0220 0110 0000 0000 0000 0000 0000 0000 0000 (high tone for
480 ms, medium tone for 320 ms, low tone for 160 ms)
Get/Set/Save support: All
Description:
This property specifies an audible tone that may be played when the host chooses. The property
is implemented as ten sets of Tone Information Bytes (TIB) as follows:

Byte Usage

1

TIB0, designates tone
0 = Silent
1 = Low
2 = Medium
3 = High
Other values may not result in a tone

2

TIB1, duration of tone in units of 10 milliseconds (e.g. 3 = 30
milliseconds). Setting this byte to zero terminates the Tone Sequence
without processing further entries

Advertising