Campbell Scientific RF401-series and RF430-series Spread Spectrum Data Radios/Modems User Manual

Page 100

Advertising
background image

Appendix I. Phone to RF401 Series

4. COM220 Dip Switches

Dip Switch Position

1

Open

2

Open

3

Open

4

Open

5

Open

6

Open

7

Open

8

Open

Refer to the COM220 manual for more information about the

COM220 Dip Switches.


5. HARDWARE

After configuring LoggerNet and the RF401s you are ready to set up

hardware. The A100 null-modem connectors (it’s not important which

connector goes to which unit) connect via SC12 cables to the COM220

and the base RF401 CS I/O port. Connect the site phone line to COM200.

Connect power to the PS100. Connect antenna to RF401. When you turn

on the PS100 supply, the RF401 receives 12V power and you will see the

LEDs light in their power-up sequence.
Remote RF401s normally connect to datalogger CS I/O ports via SC12

cables. Powering up the datalogger will start the RF401 operating. Install

an antenna (or antenna cable and yagi or collinear) and you are ready to

collect data.

NOTE

I-10