RF401-series and RF430-series Spread Spectrum Radio/Modems

5.2.1.1 Standard Setup (RF400)

FIGURE 5-5. Default Screen for the RF400 Standard Setup in

LoggerNet 4

Communication Enabled - Before communication can take place, all devices

in the chain must be enabled. When this box is selected, the radio is enabled

for communication.

Maximum Time On-Line – This field is used to define a time limit for

maintaining a connection to the device. (This may be useful in avoiding costly

communication costs, in the event that a connection to a station is inadvertently

maintained for a long period of time.) Maximum Time On-Line applies to both

scheduled connections and manual connections. However, for manual

connections from the Connect Screen, it is always best to manually disconnect

rather than relying on LoggerNet to disconnect for you.

When the device is contacted on a schedule, communication with the device

will be terminated once this time limit is exceeded. A value of 0 in this field

indicates that there is no time limit on maintaining a connection to the device.

When the device is connected in the Connect Screen and the time limit

approaches, a dialog box is displayed warning the user that Max Time On-Line

is about to be exceeded. The dialog box has

Reset Max Time and Don’t Reset

31