2 step 2 – set up remote rf401, Step 2 – set up remote rf401, 1. rf401 basic point-to-point network – Campbell Scientific RF401-series and RF430-series Spread Spectrum Data Radios/Modems User Manual

Page 21

Advertising
background image

RF401-series and RF430-series Spread Spectrum Radio/Modems

- RX LED Test -

To determine if there is a neighboring radio network in operation

using the same hopping sequence as yours, stop communications on

your network and observe your radio’s green LED for activity. A

flashing green LED would indicate that there is a nearby network

using the same hopping sequence.

Click apply after changing settings.

FIGURE 3-1. RF401 Basic Point-to-Point Network

3.2.2 Step 2 – Set Up Remote RF401

a. Connect an antenna (or antenna cable with Yagi or omnidirectional

antenna attached) to the RF401 antenna jack. The separation between the

base RF401 antenna and the remote RF401 antenna can be any convenient

distance (see Sections 3.3, Antenna Considerations, and 4.4, Compatible

Antennas).

b. Use the SC12 serial cable to connect the datalogger CS I/O port to the

remote RF401 radio’s CS I/O port. The CS I/O port on newer dataloggers

applies power to the remote RF401.

With older dataloggers lacking 12 V on pin 8 (see TABLE 3-2), you can

power the RF401 using a Field Power Cable (see above hardware list)

between the datalogger’s 12 V (output) terminals and the RF401’s

“Power” jack.

LoggerNet

AC Adapter

RS-232

CS I/O

Datalogger CS I/O

9

Advertising