Appendix B. Advanced Setup Menu

B.1 Accessing the Advanced Menu

The standard Setup Menu is described in Section 5.1, DevConfig. The

advanced Setup Menu can be accessed by configuring a terminal emulator

program such as Procomm

TM

or HyperTerminal

TM

to 9600 baud (8-N-1).

Connect the radio to the PC via the RS-232 or USB cable and press the Setup

button on the radio. The advanced setup menu is shown below.

1) Advanced Setup

a) Radio Parameters

i) Radio Address Parameters

(1) Net Address

(0 – 63)

(2) Radio Address

(0 – 1023)

(3) Net Address Mask

(0 – 3fh)

(4) Radio Address Mask

(0 – 3ffh)

(5) Hop Table

(0 – 6)

ii) Radio Standby Modes

(1) Standby Mode

(0 => 24 mA Always ON 3 => 4 mA 1/2 sec Cycle)

(4 => 2 mA 1 sec Cycle 5 => 1 mA 2 sec Cycle)

(6 => .6 mA 4 sec Cycle 7 =>.4 mA 8 sec Cycle)

(1 => Pin Sleep (PakBus Only))
(2) Time of Inactivity to Sleep

(units of 100 msec; 1 – 32767)

(3) Time of Inactivity to Long Header

(units of 100 msec; 0 – 65535)

Select 0 to always use long header

Select 65535 to never use long header

(4) Long Header Time

(units of 100 msec; 0 – 255)

iii) Radio AT Command Sequence Setup Menu

(1) AT Command Sequence Character

(any ASCII character)

(2) Silence time before Command Sequence

(units of 100 msec; 1 – 32767)

(3) Silence time after Command Sequence

(units of 100 msec; 1 – 32767)

B-1