Appendix I. Phone to RF401 Series

b. Remote RF401s

1) Radio Addresses: 1, 2, etc. (unique for each remote RF401 and

must agree with respective RF401Remote settings)

2) Protocol: Transparent

3) CS I/O Baud Rate: 9600

4) All other settings: default

If there is a neighboring RF401 network, you should change the

Hopping Sequence of base and remote RF401s to a new setting to

avoid interference.

FIGURE I-5. LoggerNet Point-to-Multipoint Setup

NOTE