Appendix K. RF401/RF411 Pass/Fail Tests

FIGURE K-1. Loop-back Test without Antennas

(9) Make sure that no antennas are attached to the RF401/RF411s

(10) Label the other RF401/RF411, “Remote”

(11) Insert jumper into the Remote RF401/RF411’s RS-232 connector pins 2

and 3 (using a U-shaped portion of a paper clip) allowing data received

from base RF401/RF411 to be transmitted back to terminal screen by

remote RF401/RF411.

RF401/RF411’s RS-232 Connector (female)

(12) Connect 12V power to Remote RF401/RF411 (Field Power Cable (Item #

14291) connected to a 12V battery (battery can be an 8 cell pack of

alkaline A, C, or D cells, or a lead-acid battery)).

If your 12V power supply is a battery pack or rechargeable battery,

make sure that the batteries are fresh or well-charged so they can

supply the 75 mA peak current needed when the RF401/RF411 is

transmitting in order to obtain valid test results.


For safety, people should maintain 20 cm (8 inches)

distance from antenna while RF401/RF411 is transmitting.

(13) Type 8 groups of 5 characters on the terminal (aaaaabbbbbccccc etc.)

(14) You should see 100% of the characters typed echo back to the screen

NOTE

CAUTION

K-4