Appendix I. Phone to RF401 Series

FIGURE I-4. Enter 250 for the Maximum Packet Size.

4. HARDWARE

After configuring LoggerNet and the RF401s you are ready to set up

hardware. The A100 null-modem connectors connect via SC12 cables to

the COM220 and the base RF401 CS I/O port. Connect the site phone

line to COM220. Connect power to the PS100. Connect antenna to

RF401. When you turn on the PS100 supply, the RF401 receives 12V

power and you will see the LEDs light in their power-up sequence.
Remote RF401s normally connect to datalogger CS I/O ports via SC12

cables. Powering up the datalogger will start the RF401 operating. Install

an antenna (or antenna cable and yagi or collinear) and you are ready to

collect data.

I-6