Appendix k. rf401/rf411 pass/fail tests – Campbell Scientific RF401-series and RF430-series Spread Spectrum Data Radios/Modems User Manual

Page 103

Advertising
background image

Appendix K. RF401/RF411 Pass/Fail

Tests

This appendix describes a method to functionally test RF401/RF411 system

components including:

PC COM port

SC12 serial cable

RF401/RF411

RF401/RF411 Antenna

Hardware/Software Required

PC with one available COM port

Terminal Program (HyperTerminal

TM

or Procomm

TM

)

Two RF401/RF411s

Two SC12 serial cables

¼ wave OMNI antenna (CSI Item # 14310)

Two power supplies rated 12 Volts, 1 Amp

(recommend AC adapter Item # 15966 and any 12 V battery pack

with Field Power Cable Item # 14291)

The following descriptions tell how to build an RF401/RF411 loop-back

test system. Recommendations are given as to where to place the

system to avoid rf-reflections (see TESTING ¼ Wave Antenna

footnote

2

in this appendix). The basic parts of the system are:

1) PC running a terminal program and a serial cable from PC COM

port to base RF401/RF411

2) Base RF401/RF411
3) Remote RF401/RF411 with RS-232 port jumper wire between TX

(pin 2) and RX (pin 3) for data loop-back.

Build the RF401/RF411 test system in the order shown:

1) TESTING SC12 CABLE and PC COM PORT
2) TESTING RF401/RF411s
3) TESTING ANTENNAS

Label components of the system “known-good” as they pass the test.

TESTING SC12 CABLE and PC COM PORT

(1) Run a terminal program such as HyperTerminal

TM

or Procomm

TM

(a) Baud rate: 9600

(b) Data, Parity, Stop Bits: 8-N-1

(c) Flow control: none

(d) Emulation: TTY

K-1

Advertising