When the IP Protocol classifier property is configured to '0', the current firmware

version automatically converts this value to 'NONTCPUDP'.

The current firmware version does not allow PPP Protocol ID classifier property to

accept its maximum allowable 4 byte hexadecimal value of 'FFFFFFFF'. As a result,

both CLI and QoS Manager only accept '000000FD' as its maximum value.

The current firmware version does not allow PPP Protocol ID classifier property to

be set to 'any' or '0'.

The current firmware version does not return the correct value of Frame Relay

Data Link Connection ID classifier property when set to value 'any'.

The current firmware version allows Protocol 'IPX 802.3' classifier property to

accept 'ETHII', 'ETHII-TAGGED' and 'ETHII-UNTAGGED' as valid Ethformat values.

As a result, both CLI and QoS Manager accept these values as valid values.

The current firmware version does not allow Minimum and Maximum bandwidth

value of '0kbps', '0mbps' or '0gbps'. Attempting to assign these values will result in

the error message "Parameter MINBANDWIDTH, value too low; minimum is

1kbps." and "Parameter MAXBANDWIDTH, value too low; minimum is 1kbps.".

The current firmware version recognizes 'DEC MOP REM CDONS' as valid

protocol attribute of classifier property instead of 'DEC MOP REM CONS' value. As

a result, both CLI and QoS Manager will return an error when set to latter value.

Valid maximum value for ICMP Code classifier property is '65535'. However, the

current firmware version allows the user to enter values up to '255' only for both

CLI and QoS Manager.

Values entered for the Max Latency scheduling property are automatically rounded

off to the nearest 16.

Values entered for the Maximum Bandwidth trafficclass property and quick set-up

property are automatically rounded off to 'Gbps'.