Revolution, Terminal block connections, You are now ready to fill and power up the spa – Balboa Water Group Revolution User Manual

Page 21: Transforming the control of hot tubs, 230v wiring installation

Advertising
background image

Revolution

Transforming the Control of Hot Tubs

21

Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,

834 b2, Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending. All material copyright of Balboa Water Group.

F3 10A 250V

F2 3A 250V

F6 0.3A 250V

J44

J24

J45

J15

W5

W4

J13

J16

J27 J25 J26 J23 J33

J28 J30 J31 J32 J29

J12

J46

J20

J57

J8

J14

J22

J21

J56

F5 30A

GND

K3

K5

K6

K2

K1

K4

K8

P2 / BL

PUMP 1

OZONE

CIRC

22117_A

RED AC

GND

GND

WHT AC

HTR

A

HTR

B

J45

J46

J24

F4 1A 250V

J18

J19

K7

T1

J15

J33

S1

S6

J31 HCE

J30 TST

J27

H3

J22

J26 H2

J25 H1

J17
J16

J29 VAC

J28 AUX FRZ

J5

LIGHT

ON

22112_A

L2

L1

N

GFCI

GND

Terminal Block Connections

Tools Needed: Phillips and flat screwdrivers, wire strippers.

Remove the four screws holding the system lid.

1.

Attach the conduit or wire connector to the system box.

2.

Strip away 1”of insulation of each wire.

3.

Pull the cable through the access hole.

4.

Push the wires into the proper terminals as indicated on the terminal

5.

block sticker.

Connect the ground wire to the Bond Lug ground bar through the hole in

6.

the system box and tighten the screw.

Tighten the screws on the terminal block; torque between 21 and 23 in lbs.

7.

TIP

When installing and routing wires to the terminal block, providing service loops
to incoming wiring is highly recommended. Service loops provide an extra
length of wire in the event of future serviceability.

You are now ready to fill and power up the spa.

Bond Lug
for
Spa Equipment

Main Electrical Connections
In BP1500 System

F3 10A 250V

F2 3A 250V

F6 0.3A 250V

J44

J24

J45

J15

W5

W4

J13

J16

J27

J25

J26

J23

J33

J28

J30

J31

J32

J29

J12

J46

J20

J57

J8

J14

J22

J21

J56

F5 30A

GND

K3

K5

K6

K2

K1

K4

K8

P2 / BL

PUMP 1

OZ

ONE

CIRC

22117_A

RED AC

GND

GND

WHT AC

HTR

A

HTR

B

J45

J46

J24

F4 1A 250V

J18

J19

K7

T1

J15

J33

S1

S6

J31 HCE

J30 TST

J27

H3

J22

J26 H2

J25 H1

J17

J16

J29 VAC

J28 AUX FRZ

J5

LIGHT

ON

22112_A

L2

GND

L1

N

240V Wiring Installation

120V Wiring Installation

L2

L1

N

F3 10A 250V

F2 3A 250V

J44
J48

J1
J2

J24

J45

J49

J15

J16

J47

J13

J27

J25

J26

J23

J33

J28

J30

J31

J32

J29

J12

J46

J20

J57

J8

J14

J22

J21

J56

GND

K3

K5

K6

K2

K1

K4

OZ

ONE

22117_B

RED AC

GND

GND

WHT AC

HTR A

HTR B

UNFUSED

T 150 m A

250V

F5 T 30A

CIRC

1S PUMP 1

1S PUMP 2

GRN

N

L1

N/A

ADDED JUMPER FOR

CE INSTALLATIONS

BLU

BRN

230V Wiring Installation