Revolution, System-related messages (cont.), Warning – Balboa Water Group Revolution User Manual
Page 40

Revolution
Transforming the Control of Hot Tubs
40
Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,
834 b2, Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending. All material copyright of Balboa Water Group.
HOT FALT ---- CALL FOR SRVC ----
A Pump appears to have been Stuck ON when spa was last powered
POWER DOWN THE SPA. DO NOT ENTER THE WATER. Contact your
dealer or service organization.
This fault can be reset by powering up in Test Mode.
WARNING:
HOT FALT indicates a serious condition and should not be treated lightly. The
spa probably had a pump stuck in the ON position and could not be turned
off, thereby overheating the water. The system tripped the GFCI to avoid
additional heating.
NOTE: The GFCI Trip Feature must be enabled for this safety feature to function.
The system should be monitored carefully and the main circuit board may need
to be replaced.
A Pump Appears to have been Stuck ON when spa was last powered UP
System-Related Messages (cont.)
STUK PUMP ----
Water may be overheated. POWER DOWN THE SPA. DO NOT ENTER THE
WATER. Contact your dealer or service organization.
A Pump Appears to be Stuck ON