Heater Related Messages

HTR FLOW LOSS ----

There may not be enough water flow through the heater to carry the heat away
from the heating element. Heater start up will begin again after about 1 min. See
“Flow Related Checks” below.

HTR FLOW FAIL ----

There is not enough water flow through the heater to carry the heat away from
the heating element and the heater has been disabled. See “Flow Related
Checks” below. After the problem has been resolved, you must press any button
to reset and begin heater start up.

HTR MAY BE DRY ---- WAIT ----

Possible dry heater, or not enough water in the heater to start it. The spa is shut
down for 15 min. Press any button to reset the heater start-up. See “Flow Related
Checks” below.

Heater Flow is Reduced (HFL)

Heater Flow is Reduced (LF)*

Heater may be Dry (dr)*

* This message can be reset from the topside panel with any button press.

HTR DRY ----

There is not enough water in the heater to start it. The spa is shut down. After
the problem has been resolved, you must press any button to reset and restart
heater start up. See “Flow Related Checks” below.

Heater is Dry*