Revolution, Heater related messages (cont.) – Balboa Water Group Revolution User Manual
Page 37

Revolution
Transforming the Control of Hot Tubs
37
Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,
834 b2, Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending. All material copyright of Balboa Water Group.
Heater Related Messages (cont.)
HTR TOO HOT ---- (OHH)
One of the water temp sensors has detected 118°F (47.8°C) in the heater and the
spa is shut down. You must press any button to reset when water is below 108°F
(42.2°C). See “Flow Related Checks” below.
PRES BTTN TO RSET
Some errors may require power to be removed and restored.
A reset message may appear with other messages.
Heater is too Hot (OHH)*
Press Button to Reset
* This message can be reset from the topside panel with any button press.
WATR TOO HOT ---- (OHS)
One of the water temp sensors has detected spa water temp 110°F (43.3°C)
and spa functions are disabled. System will auto reset when the spa water
temp is below 108°F (42.2°C). Check for extended pump operation or high
ambient temp.
Water is too Hot - (OHS)