Unpacking your tool, Before use, Product familiarisation – Silverline Rotary Laser Level Kit User Manual

Page 6: Setting up, Calibrating your laser level

Advertising
background image

www.silverlinetools.com

5

273233

Rotary Laser Level Kit

Safety Rules for Laser Lights

WARNING: Do not direct the laser light towards yourself or other persons
• Do not point the laser at reflective sheet material as the surface could

direct the beam back at the operator or other persons in the vicinity

• Changes to or replacement of the laser light assembly should only be

carried out by the manufacturer or an authorised agent

• Maintain the laser in accordance with the manufacturer’s instructions
• CAUTION: Failure to follow safety rules may result in flash blindness and

hazardous radiation exposure

Unpacking Your Tool

• Carefully unpack and inspect your tool. Fully familiarise yourself with all

its features and functions

• Ensure that all parts of the tool are present and in good condition. If

any parts are missing or damaged, have such parts replaced before
attempting to use this tool

Before Use

Insert batteries

• Remove the cover from the battery compartment in the rear of the Rotary

Laser Level Unit (3)

• Insert the batteries, making sure to get the positive and negative

terminals the correct way round, as shown on the cover of the battery
housing

• Replace the cover

Product Familiarisation

1

Carry Case

2

Rotary Head

3

Rotary Laser Level Unit

4

Y Vial

5

Frame

6

X Axis Levelling Screw

7

Y Axis Levelling Screw

8

Control Button

9

Plumbers Vial

10 X Vial
11 Screwdriver
12 Tripod

Setting up

For Levelling

• Screw the Tripod (12) into the brass fitting on the Frame (5), so that the

Rotary Head (2) is uppermost

For Plumbing

• Screw the Tripod (12) into the alternative fitting (without brass insert) on

the Frame (5), so that the Control Button (8) is uppermost

In all cases

• Use the snap-fit connectors to extend and lock the tripod legs, and the

winder handle to extend the mount for the rotary laser level as needed

Calibrating Your Laser Level

Checking Horizontal Rotational Level

1. Position your laser level approximately 10m away from the wall

ensuring that the Control Button (8) is facing the wall. Use the Levelling
Screws (6 & 7) to adjust the level so that the bubble is in the centre
of each vial

2. Turn the power on for static laser beam, and rotate the Rotary Head (2)

manually (if needed) so that the laser beam is pointing directly ahead
on the wall. Mark as point A

3. Turn power off and rotate the unit 180˚ so that the back of the unit is

now facing the original wall

4. Re-level the unit
5. Turn the power on for static laser beam, then rotate the Rotary Head

(2) so that the laser beam is pointing onto the original wall. Mark as
point B

6. Measure the vertical distance to both points A and B from the

floor. No adjustments to the laser level are necessary if the vertical
measurements have a difference of 3mm or less

Correcting Horizontal Rotational Level

1. Adjust the X Axis Levelling Screw (6) so the laser beam shows midway

between points A and B. (This will cause the bubble in the X Vial (10) to
shift from the centre)

2. Centre the X vial bubble by adjusting the X vial calibration screw

(adjacent to the vial) with Screwdriver (11) supplied

3. Re-check the accuracy of the laser by repeating the calibration

process as necessary

Checking Vertical Rotational Level

1. Position the unit on its tripod on the floor approximately 15m from the

base of the wall. The right side of the unit should face the wall. Level
the unit by adjusting the Y Axis Levelling Screw (7)

2. Mark a point A on the lower part of the wall. Turn the power on and

manually direct the laser beam to point A

3. Turn the rotary head so the laser beam moves approximately 4.5m

upwards on the wall. Mark as point B

4. Rotate the unit 180˚ so the left side of the unit faces the wall. Re-level

the unit by adjusting the Y axis levelling screw. Manually direct the
laser beam to point A

5. Turn the rotary head so that the laser beam is at the same height

as point B. Mark as point C. No adjustments are necessary if the
difference between points B and C is 2mm or less

Correcting Vertical Rotational Level

1. Adjust the Y Axis Levelling Screw (7) so laser beam is midway between

points B and C. (This will cause the bubble in the Y Vial (4) to shift
from the centre)

2. Centre the Y vial bubble by adjusting the Y vial calibration screw

(adjacent to the vial) with Screwdriver (11) supplied

3. Re-check the accuracy of the laser by repeating the calibration

process as necessary