WARNING
Actuators can be activated unintentionally and the
SPC200 can be damaged if modules are added or
removed while the power supply is switched on.
Before undertaking installation and/or maintenance
work, switch off the following in the sequence
specified here:
1. the compressed air supply
2. the load voltage and the operating voltage

supplies for the SPC200 and, if applicable, the
load voltage supply for the axis interface string.

When fitting the modules into the rack, proceed as
follows:

Fitting

modules

1. Switch off the compressed air supply and the oper-

ating voltage supply.

2. If applicable, remove the blind plate.

3. Hold the module by the front plate and push it into

the guide rail. Make sure that the modules are not
tilted when they are pushed in and that no compo-
nents on the printed circuit board are damaged.

4. Make sure that the plugs of the terminal strips are

correctly aligned. Using light pressure, push the mo-
dule in completely. The safety catches will then lock
automatically (see Fig. 2/1).

2. Fitting

SPC200-COM-IBS 0503a