Specifications – WIKA LSO.25 User Manual

Page 10

Advertising
background image

10

WIKA operating instructions models LSO.06, LSO.25

13334603.01 09/2010 GB/D/F/E

3. Specifications

GB

3. Specifications

3.1 Transducer model LSO.06

General data

Measuring accuracy

±0.5 mm

Ambient light

max. 100 Lux

Mounting position

any

Weight

Standard version

High and low temperature version

0.77 kg +9.3 g/cm ML

1)

1.07 kg +9.3 g/cm ML

1)

1) ML = Measuring length

Design data

Medium temperature

Standard version

High and low temperature version

-65 ... +250 °C

-269 ... +400 °C

Ambient temperature

-65 ... +95 °C

Working pressure

0 ... 25 MPa (0 ... 250 bar)

High pressure version

0 ... 50 MPa (0 ... 500 bar)

Materials

Sensor case

Light guide

Packing

Case

1.4571 (option: hastelloy, other materials on request)

clad core glass (option: quartz, sapphire (only max.

ML = 60 mm))

graphite

stainless steel

Ex ignition protection type

II 1/2 G Ex ib op is IIC T5, T6

T6: to 60 °C, T5: to 75 °C

ZELM 10 ATEX 0440

Electrical data

Cable gland

M20 x 1.5, Ex: blue

Terminal connection

3 x 2.5 mm²

Ingress protection

IP 65 per EN 60529

For further specifications see WIKA data sheet LM 31.10 and the order documentation.

Advertising