Design and function – WIKA LSO.25 User Manual

Page 17

Advertising
background image

WIKA operating instructions models LSO.06, LSO.25

17

13334603.01 09/2010 GB/D/F/E

4. Design and function

GB

For explosion protected version please note the following:

The amplifier is designed as a plug-in card for a 19" plug-in card. The plug-in card alone

doesn't fulfill the ingress protection IP 20 in accordance with EN 60529: 1991. It only is

intended for the installation into a suitable rack which guarantees the minimum ingress

protection IP 20. Not used plug-in places have if necessary to be covered with blind plates.

The distances and tracking distances particularly are between the individual plug-in cards

as well as the intrinsic safe and not intrinsic safe circuits, the requirements on the wiring as

well as the excess temperature and the dissipation power converted in the assemblies are

to take into account according to EN 60079-11:2007. To avoid mistakes, the switch ampli-

fiers are provided with an encoding system. It has to be made sure that the counter-strip is

executed availably and identically in the 19" rack.

Default coding

Supply voltage

version

Encoder-strip rack,

provided at these positions

with coding pins

Encoder-strip plug-in card,

provided at these positions with one

coding pin

AC 230 V

B-C-D-E-F-G-H-J

1

AC 115/120 V

A, C-D-E-F-G-H-J

2

AC 24 V

A-B, D-E-F-G-H-J

3

DC 24 V

A-B-C, E-F-G-H-J

4

Encoder-strip plug-in card

Encoder-strip rack

Example: AC 230 V supply voltage version

We exclusively recommend the use of suitable racks for the guarantee of the requirements

to WIKA.

Advertising