23 interrupt mask 2 (address 20h), 1 dacx clip interrupt mask, 1 test mode error – Cirrus Logic CS4234 User Manual

Page 68: 2 serial port error, 3 clocking error, 4 adcx overflow, Cs4234

Advertising
background image

DS899F1

68

CS4234

6.23 Interrupt Mask 2 (Address 20h)

6.23.1

DACx Clip Interrupt Mask

Allows or prevents a DACx Clip event from flagging the interrupt pin.

6.24 Interrupt Notification 1 (Address 21h) (Read Only)

6.24.1

Test Mode Error

A Test Mode Error occurred since the last clearing of the Interrupt Notification register.

6.24.2

Serial Port Error

A Serial Port Error occurred since the last clearing of the Interrupt Notification register.

6.24.3

Clocking Error

A Clocking Error occurred since the last clearing of the Interrupt Notification register.

6.24.4

ADCx Overflow

An ADCx Overflow occurred since the last clearing of the Interrupt Notification register.

7

6

5

4

3

2

1

0

Reserved

Reserved

Reserved

MASK

DAC5 CLIP

MASK

DAC4 CLIP

MASK

DAC3 CLIP

MASK

DAC2 CLIP

MASK

DAC1 CLIP

MASK
DACx CLIP

In the event of a DACx Clip event, Interrupt Pin will:

0

Be Flagged

1

Not be flagged

7

6

5

4

3

2

1

0

TST MOD ERR

SP ERR

CLK ERR

Reserved

ADC4 OVFL

ADC3 OVFL

ADC2 OVFL

ADC1 OVFL

TST MOD ERR

Since the last clearing of the Interrupt Notification Register, a Test Mode Error:

0

Has Not Occurred

1

Has Occurred

SP ERR

Since the last clearing of the Interrupt Notification Register, a Serial Port Error:

0

Has Not Occurred

1

Has Occurred

CLK ERR

Since the last clearing of the Interrupt Notification Register, a Clocking Error:

0

Has Not Occurred

1

Has Occurred

ADCx OVFL

Since the last clearing of the Interrupt Notification Register, an ADCx Overflow Error:

0

Has Not Occurred

1

Has Occurred

Advertising