To manually configure the IntraSwitch 5308FL with an IP
address via the unit’s Console port, use a VT100 terminal or a
VT100 terminal emulator running on a workstation or personal
computer (PC) to connect to the IntraSwitch 5308FL’s Local
Management Interface.

1

Using a straight-through RS-232 cable with a 9-pin
male D-subminiature plug at one end, connect a
terminal or workstation (PC) running a terminal
emulator to the

Console port on the front of the

IntraSwitch 5308FL.

Important!

If you are using a Macintosh, you

need a special cable to connect to the
IntraSwitch 5308FL’s Console port. Contact
Asanté Technical Support (see Appendix E) for
assistance.

Figure 2-7

Connecting to the Console port

2

Make sure both units’ power is turned on.

If using a PC with a terminal emulator, make
sure it is configured with the following terminal
settings:

❏ Bits Per Second: 9600
❏ Data Bits: 8
❏ Parity: None
❏ Stop Bits: 1
❏ Flow Control: None

IntraSwitch 5308FL

100 Mbps

Max Util

FDP / COL

Data

Link

10/100 1 2 3 4 5 6 7 8 MII 1 MII 2

10/100

Console

RS-232

1

2

3

4

5

6

7

8

IntraSwitch 5308FL

Stand-Alone Terminal
or PC Running Terminal
Emulation Software

Console Port
(female; requires a male connector)

Straight-Through