Out-of-band management – Asante Technologies 5308F User Manual

Page 52

Advertising
background image

Setting Up For Management

Page 4-4

Out-of-Band

Management

Out-of-band network management allows you to configure,
manage, and monitor the IntraSwitch 5308FL and each of its
ports. You can perform these functions via the following
method:

By attaching a terminal (or a terminal emulator)
to the IntraSwitch 5308FL’s Console port and
using the menu-driven

Local Management

Interface.

Out-of-band network management is guaranteed even when the
in-band Ethernet network is down.

To access the IntraSwitch 5308FL’s Local Management Interface
using out-of-band management:

1

Connect a stand-alone terminal or a PC running a
terminal emulator directly to the IntraSwitch
5308FL’s Console port using a

straight-through

RS-232 serial cable with a male connector.

Important!

If you are using a Macintosh, you

need a special cable to connect to the
IntraSwitch 5308FL’s Console port. Contact
Asanté Technical Support (Appendix E) for assis-
tance.

Figure 4-2

Connecting to the Console port

2

Make sure both units’ power is turned on.

If using a PC with a terminal emulator, make
sure it is configured with the following terminal
settings:

IntraSwitch 5308FL

100 Mbps

Max Util

FDP / COL

Data

Link

10/100 1 2 3 4 5 6 7 8 MII 1 MII 2

10/100

Console

RS-232

1

2

3

4

5

6

7

8

IntraSwitch 5308FL

Stand-Alone Terminal
or PC Running Terminal
Emulation Software

Console Port
(female; requires a male connector)

Straight-Through
RS-232 Cable