This tab includes the following:

Output Density

Measured

The values that are measured from the printed target.

Target

The expected values of the output density.

Minimum Accepted

The minimum measured value of the output density that
is accepted for correction.

Properties—The parameters selected when the calibration
table was created.

Calibration table Info Graph tab

During printing, the IC-309 print controller automatically replaces
the CMYK values in the RTP file with new values that compensate
for the printer’s current performance level.

This tab includes the following:

Separations

The graph displays cyan, magenta, yellow, and black
separations. You can view information about each
separation by clicking the desired separation button, or you

90

Chapter 7—Managing color