12. In the Save Calibration Results area, select if you want the

calibration results saved As default name or select Save as,
and enter a name for the calibration table in the text box.

13. In the Apply to area, choose if you want the calibration table

to apply to All Media Types, or choose Select, and select the
respective media types to which you want the calibration table
to apply.

14. Click Finish.

The new calibration table is saved and applied to the next job
that prints.

Using the X-Rite i1iO spectrophotometer to create a calibration
table

Requirements:

Your spectrophotometer must be connected to the USB port on
the IC-309 print controller. The first time you connect the device
to the IC-309 print controller you are notified that the driver is
being installed. Wait for the driver installation to finish before
proceeding further.

Before inserting the i1 into the arm of the i1iO, make sure that
the i1 spectrophotometer is calibrated by placing it on its
calibration plate. Refer to the spectrophotometer product
documentation for more information.

Insert the i1 spectrophotometer in the arm of the i1iO
spectrophotometer and make sure that the arm is in its docking
position.

The Print queue must be ready for printing (not suspended),
and the printer warmed up.

Using the X-Rite i1iO spectrophotometer to create a calibration table

37