Internal cleaning 124, Introduction 124, Internal cleaning – Konica Minolta Magicolor 7300 User Manual

Page 132

Advertising
background image

Introduction

124

When does the printer need cleaning?

Internal Cleaning

The printer pauses to do an automatic internal cleaning cycle, also known as
the calibration cycle, at specified times.

Calibration
Cycle

Time of
Calibration
(Seconds)

Occurrence

Description

Warmup
Time

99.9 or less

At power on

Adjusts maximum
density during
warmup

Light
Calibration

99.9 or less

At waking from deep
sleep Energy Saver
mode

Adjusts maximum
density

Heavy
Calibration

All four units
at the same
time: 241
One unit:198

At replacement of
print unit
assembly(ies)

Adjusts half tone
(gamma curve),
registration, and
maximum density

Intermittent
Printing

86 or less

At detection of inside
temperature change
more than the preset
threshold (as short as
four minutes)*

Adjusts maximum
density

Continuous
Printing

26

At detection of inside
temperature change
more than the preset
threshold (as short as
four minutes)**

Adjusts maximum
density

Toner
Cartridge
Replacement

All four
cartridges at
the same
time: 241
One
cartridge: 198

At replacement of
toner cartridge(s)

Allows engine to
detect cartridge
installation, adjusts
maximum density

Fuser Unit
Replacement

99.9 or less

At replacement of the
fuser unit

Adjusts maximum
density

Notes:

* Calibration starts after the job. However, if the job is very

long, it is considered as a continuous job and calibration
starts in the middle of the job.

** Calibration starts in the middle of the job.

Advertising