Table 4-2. typical spreadsheet for a pca 65, Name of fuel (up to 16 characters) fuel 8, Flue gas temperature ta 9 – Bacharach Portable Combustion Analyzer 24-9351 User Manual

Page 32: Air temperature tl 10, Temperature unit of measure (f or c) c/f 11, Concentration in % o2 12, Concentration in % c2 13, Co concentration in ppm co 14, Co referenced to 0% o, No concentration in ppm nx 16

Advertising
background image

PCA

Instruction 24-9351

4-16

Operation

TABLE 4-2. TYPICAL SPREADSHEET FOR A PCA 65

Line 1: Column Headings
Line 2: Typical Combustion Readings
Line 3: Typical Draft Reading

SN

ID1

ID2

ID3

TIME

DATE

FUEL

TA

TL

C/F

O2

AX1020

ID LINE 1

ID LINE 2

ID LINE 3 9:03:27 19.01.1999

NATGAS

190

20

C

4

AX1020

ID LINE 1

ID LINE 2

ID LINE 3 9:10:35 19.01.1999

C2

CO

CU

NX

NU

qA

LA

DR

MB/PA/WC

9.5

12

15

10

12

8.1

1.24

-0.25

MB

-0.25

MB

TABLE 4-1. COMMA-DELIMITED FIELDS

Field

Data Name or Value

Label in Column

Headings

1

Instrument serial number

SN

2

ID line 1 (up to 16 characters)

ID1

3

ID line 2 (up to 16 characters)

ID2

4

ID line 3 (up to 16 characters)

ID3

5

Time of test (hh:mm:ss)

TIME

6

Date of test (dd.mm.yyyy)

DATE

7

1

Name of fuel (up to 16 characters)

FUEL

8

1

Flue gas temperature

TA

9

1

Air temperature

TL

10

1

Temperature unit of measure (F or C)

C/F

11

1

O

2

concentration in %

O2

12

1

CO

2

concentration in %

C2

13

1,2

CO concentration in ppm

CO

14

1,2

CO referenced to 0% O

2

in ppm

CU

15

1,3

NO concentration in ppm

NX

16

1,3

NO referenced to 0% O

2

in ppm

NU

17

1

qA in %

qA

18

1

Lambda

LA

19

Draft measurement

DR

20

Draft unit of measure

MB/PA/WC

1

Empty data field for draft tests

2

Empty data field for PCA Models 40 and 45

3

Empty data field for PCA Models 40, 45, 50, and 55

Advertising