SECTION 3 - MACHINE CONTROLS AND INDICATORS

3-4

– JLG Lift –

3121264

NOTE:

Auxiliary power only works if there is no engine oil pres-
sure, and is disabled if engine is running.

Functions will operate at a slower than normal rate
because of the lesser flow of hydraulic fluid delivered.

WHEN USING AUXILIARY POWER, DO NOT OPERATE MORE THAN ONE
FUNCTION AT A TIME. (SIMULTANEOUS OPERATION CAN OVERLOAD
THE AUXILIARY PUMP.

9. Engine Start/ Auxiliary Power Switch /Function Enable

To start the engine, the switch must be held
"UP" until the engine starts.

To use auxiliary power, the switch must be
held “DOWN” for duration of auxiliary pump
use. Aux power can only be used if the engine
is not running.

The enable switch must be held "DOWN" to
enable all boom controls when the engine is
running.

10. Articulating Jib

This switch provides raising and lowering of the jib.

ONLY USE THE PLATFORM LEVELING OVERRIDE FUNCTION FOR
SLIGHT LEVELING OF THE PLATFORM. INCORRECT USE COULD CAUSE
THE LOAD/OCCUPANTS TO SHIFT OR FALL. FAILURE TO DO SO COULD
RESULT IN DEATH OR SERIOUS INJURY.

11. Platform Leveling Override

This switch allows the operator to adjust the automatic
self leveling system. This switch is used to adjust plat-
form level in situations such as ascending/descending a
grade.

12. Platform Rotate

This switch permits rotation of the platform.

13. Jib Swing

This switch allows the operator to swing the jib to the left
and right.