7. Platform Overload Indicator (If Equipped)

Indicates the platform has been overloaded.

8. Boom Control System Warning Indicator

Indicates the platform is outside the operating area and
operation of certain boom functions may be disabled
(i.e. lift, telescope). Attempts to use the disabled func-
tions cause the indicator to flash and an alarm to sound.
Immediately return the platform to the ground. If the indi-
cator remains lit, a boom control system fault or failure
has been detected. If a fault or failure is discovered, the
system must be repaired by JLG authorized service per-
sonnel before the machine can be used.

9. Boom Control System Calibrated Indicator

When the Boom Control System Test Button is pushed,
illuminates to indicate that the Boom Control System is
calibrated properly.

Platform Station

(See Figure 3-3., Platform Control Console)

TO AVOID SERIOUS INJURY, DO NOT OPERATE MACHINE IF ANY CON-
TROL LEVERS OR TOGGLE SWITCHES CONTROLLING PLATFORM
MOVEMENT DO NOT RETURN TO THE OFF OR NEUTRAL POSITION
WHEN RELEASED.

1. Power/Emergency Stop

A two-position red mushroom shaped switch furnishes
power to PLATFORM Controls when pulled out (on).
When pushed in (off), power is shut off to the platform
functions.

Within about 2 seconds of pulling the switch out, the
machine will perform a diagnostic check of the various
electrical circuits, and if everything is OK, the platform
alarm will beep once. During this time the lights on the
indicator panel will also blink once as a bulb check.