11
Parameters
State
Define the call state change.
Valid values:
ringing – ringing start
connected – successful call connection
terminated – call termination
Direction
Define the call direction.
Valid values:
incoming – incoming calls
outgoing – outgoing calls
any – both directions
The parameter is optional, the default value is
.
any
Example
Event generated by termination of any outgoing call:
Event.CallStateChanged: State=terminated; Direction=outgoing
Event.InputChanged
The
block defines the event generated by a change of the logic level
InputChanged
on the defined digital input.
Parameters
Input
Define the logic input.
Valid values:
tamper – tamper switch input
input1 – digital input 1