Event.inputchanged, Parameters, Example – 2N Helios IP Automation v2.5 User Manual

Page 11

Advertising
background image

11

2N TELEKOMUNIKACE a.s., www.2n.cz

®

Parameters

State

Define the call state change.

Valid values:

ringing – ringing start

connected – successful call connection

terminated – call termination

Direction

Define the call direction.

Valid values:

incoming – incoming calls

outgoing – outgoing calls

any – both directions

The parameter is optional, the default value is

.

any

Example

Event generated by termination of any outgoing call:

Event.CallStateChanged: State=terminated; Direction=outgoing

Event.InputChanged

The

block defines the event generated by a change of the logic level

InputChanged

on the defined digital input.

Parameters

Input

Define the logic input.

Valid values:

tamper – tamper switch input

input1 – digital input 1