2N TELEKOMUNIKACE a.s., www.2n.cz

®

Block diagram

The rising edge on the tamper input (1: Event.InputChanged) initiates calling to the
defined telephone number (5: Action.BeginCall) in case the defined condition is met.
The condition (4: Condition.FlipFlopRS) is validated by the intercom restart or entering
the selected code (2: Condition.CodeEntered) from the numerical keypad. If another
code is entered (3: Condition.CodeEntered), the condition will be invalid.

Intercom settings

1: Event.InputChanged: Input=tamper; Edge=rising

2: Event.CodeEntered: Code=164575

3: Event.CodeEntered: Code=111

4: Condition.FlipFlopRS: SetEvent=3; ResetEvent=2; ResetValue=1

5: Action.BeginCall: Number=1111; Event=1; Condition=4

Door Opening by RFID Card

Specification

Activate the door contact switch by entering the proper RFID card.

Block diagram

Entering an RFID card with the defined ID (1: Event.CardEntered) activates switch 1
(2: Action.ActivateSwitch).