Event.codeentered, Example, Parameters – 2N Helios IP Automation v2.5 User Manual

Page 9

Advertising
background image

9

2N TELEKOMUNIKACE a.s., www.2n.cz

®

%1,

, ..,

for quick dial buttons

%2

%54

any for any button (default value).

Separate the values with a comma while defining more keys than one.

SuppressTones

Suppress sound signalling initiated by pressing of a non–programmed quick dial button.
The parameter is optional.

Valid values:

0 – tones are not suppressed

1 – tones are suppressed (default value)

Example

Event generated by pressing of # and quick dial button 3 or 4:

Action.KeyPressed: Key=#, %3, %4

Event.CodeEntered

The

block defines the event generated by entering of the numerical code

CodeEntered

and confirmation with the * key (for numerical keypad models only).

Parameters

Code

Define the numerical code.

Valid values:

Numerical code – 12345, e.g.

SuppressTones

Suppress sound signalling initiated by receiving of an invalid numerical code. The
parameter is optional.

Valid values:

0 – tones are not suppressed

1 – tones are suppressed (default value)

Advertising