Condition.inputstate, Example, Parameters – 2N Helios IP Automation v2.5 User Manual
Page 22
22
Example
The condition is met for an inactive call:
Condition.CallState: State=Inactive
Condition.InputState
The
block defines the condition to be met in case the defined logic level
InputState
gets connected to the defined digital input.
Parameters
Input
Define the digital input.
Valid values:
tamper – tamper switch
input1 – digital input 1
input2 – digital input 2
cr_input1 – digital input 1 on card reader
cr_input2 – digital input 2 on card reader
There may be different lists of valid values for different
models; refer
2N Helios IP
®
to the Available Digital Inputs and Outputs subsection.
Level
Define the required digital input level. The parameter is optional.
Valid values:
0 – logic 0
1 – logic 1 (default value)
Example
The condition is met for an activated tamper switch (device not open):
Condition.InputState: Input1=tamper; Level=0