Condition.inputstate, Example, Parameters – 2N Helios IP Automation v2.5 User Manual

Page 22

Advertising
background image

22

2N TELEKOMUNIKACE a.s., www.2n.cz

®

Example

The condition is met for an inactive call:

Condition.CallState: State=Inactive

Condition.InputState

The

block defines the condition to be met in case the defined logic level

InputState

gets connected to the defined digital input.

Parameters

Input

Define the digital input.

Valid values:

tamper – tamper switch

input1 – digital input 1

input2 – digital input 2

cr_input1 – digital input 1 on card reader

cr_input2 – digital input 2 on card reader

There may be different lists of valid values for different

models; refer

2N Helios IP

®

to the Available Digital Inputs and Outputs subsection.

Level

Define the required digital input level. The parameter is optional.

Valid values:

0 – logic 0

1 – logic 1 (default value)

Example

The condition is met for an activated tamper switch (device not open):

Condition.InputState: Input1=tamper; Level=0