2N TELEKOMUNIKACE a.s., www.2n.cz

®

Example

Activate switch 1 if the event defined on row 2 arises and the condition defined on row
3 is met:

Action.ActivateSwitch: Switch=1; Event=2; Condition=3

Action.SetOutput

The

block defines the action necessary for setting of the intercom output to

SetOutput

the required level.

Parameters

Event

Define the event that launches the action.

Condition

Define the condition to be met to execute the action. This parameter is optional.

Output

Define the output to be set.

Valid values:

relay1 – relay 1 on basic unit

relay2 – relay 2 on basic unit

output1 – output 1 on basic unit

output2 – output 2 on basic unit

cr_relay1 – relay 1 on card reader

cr_relay2 – relay 2 on card reader

cr_output – output 1 on card reader

redled - red LED indicator

led1 – LED 1 indicator

led2 – LED 2 indicator

led3 – LED 3 indicator

There may be different lists of valid values for different

models; refer

2N Helios IP

®

to the Available Digital Inputs and Outputs subsection.