2N Helios IP Automation v2.5 User Manual
Page 31
31
Intercom settings
1: Event.CardEntered: Card=0*0000
2: Action.ActivateSwitch: Switch=1; Event=1
Alarm (Dispatching Office Call) Caused by Over
2-Min Long Door Opening
Specification
Call the dispatching office in case the door remains open for more than 2 minutes. It is
supposed in the example that the door opening signalling contact is connected to
Input1.
Block diagram
Whenever the door opens, the rising edge on Input1 signal (1: Event.InputChanged)
calls the defined telephone number (4: Action.BeginCall) with a 120s delay (2:
Event.Delay).The call is only executed if the door remains open for more than 120s (3:
Condition.InputState).
Intercom settings
1: Event.InputChanged: Input=input1; Edge=rising
2: Event.Delay: Delay=120s; StartEvent=1
3: Condition.InputState: Input=input1; Level=1
4: Action.BeginCall: Number=1111; Event=2; Condition=3