2. Package Contents

AirLive POE-5010HD User’s Manual

7

2. GPIO/RS-485: Connect to a local keyboard controller.

„ DI/ DO: Connect to sensor in and alarm out devices

Cable for I/O connectors:

PIN

SPECIFICATION

1 Ground (Common)

GND

2 GPIO Out #1

Close circuit current maximum: 70mA AC or 100mA

Output resistance: 30 ohm

Open circuit voltage maximum: 240V AC or 350V DC

3 GPIO In #1

4 GPIO In #2

Action high voltage: 9~40 VDC

Dropout voltage: 0 VDC

5 AC24V Power Input

6 AC24V Power Input

AC power: 24V

7 RS-485 TX+

8 RS-485 TX-

Compliant to RS-485

3. DC-in Jack: The input power is 12VDC.

Note that supply the power to the Network Camera with the power adapter included in

package.

4. Audio I/O Connectors

„

MIC in (audio in): Connect a microphone to the network camera.

„ Line out (audio out): Connect a loud speaker to the network camera. This

function is for voice alerting and two-way audio.

5. Iris Level: It is used only when the DC-Iris lens is connected to the camera. This

screw-knob allows you to adjust the brightness of the video images from the DC-Iris

lens.

6. SD Card Slot: SD Card Slot allows you to insert a memory card for expansion of

storage.