Appendix A: Alarm I/O Connector



AirLive POE-5010HD User’s Manual

46

Appendix A: Alarm I/O Connector

Some features of the Camera can be activated by the external sensor that senses physical

changes in the area Camera is monitoring. These changes can include intrusion detection

or certain physical change in the monitored area. For examples, the external sensor can be

a door switch or an infrared motion detector. These devices are customer provided, and are

available from dealers who carry surveillance and security products. Electrically, they must

be able to provide a momentary contact closure.

This Camera provides wires for general I/O terminal and RS485 interface as below:

Cable for I/O connectors:

PIN

SPECIFICATION

1 Ground

(Common)

GND

2 GPIO Out #1

Close circuit current maximum: 70mA AC

or 100mA

Output resistance: 30 ohm

Open circuit voltage maximum: 240V AC or

350V DC

3 GPIO In #1

4 GPIO In #2

Action high voltage: 9~40 VDC

Dropout voltage: 0 VDC

5 AC24V Power

Input

6 AC24V Power

Input

AC power: 24V

7 RS-485 TX+

8 RS-485 TX-

Compliant to RS-485

User can refer to the schematic below to make a proper connection between I/O connector

and external sensor and output device.