Dimensions and Technical Specifications

RTCSmp Built-In Module-Line Dual/Quad Cooktops


12

Part # 4532415 Rev 3 (8/19/14)

3.6

Operating Conditions

Max. Tolerance of Nominal Supply Voltage

+6 /-10 %

Network Impedance (Zmax.)

0.25Ω

Supply frequency

50/60 Hz

Amperage Nominal Value — 400V, 3Ph

10A for the 7kW generator (4 x 1.5mm

2

)

15A for the 10kW generator (4 x 2.5mm

2

)

2 x 10A for the 14kW generator (2 x (4 x 1.5mm

2

))

Amperage Nominal Value — 208V, 3Ph

20A for the 7kW generator (4x AWG 10)

29A for the 10kW generator (4x AWG 8)

2 x 20A for the 14kW generator (2 x (4 x AWG 10))

Ingress Protection class

IP X0 (Protection by customer required.)

Maximum Ambient Temperature

In Storage -4°F to +158°F (-20°C to +70°C)

In Operation +41°F to +104°F (+5°C to +40°C)

Maximum Relative Air Humidity

In Storage 10% to 90%

In Operation 30% to 90%

Temperature/Power Regulator

Potentiometer 10 kOhm

LED Indicator Lamp

24VDC / max. 40mA (Green)

Clearance from materials for generator

Min. 1.57”(40mm) for air intake and exhaust openings

Min. 0.39”(10mm) for side clearance

Min. Induction Cooking Pan Diameter

5” (12cm)

Max. Air Flow of Fan is 70.63 cfm (120 m

3

/h), Fresh Air Inlet Opening of 10.08 sq. in. (6500 mm

2

) is required.

3.7

Compliances

North American models:

ETL recognized* in compliance with UL 197, CSA C22.2 No.109, NSF-4. Complies with FCC part 18, ICES-001

CE models comply with the latest European Norms:

EN 60335-1, EN 60335-2-36, EN 62233 (EMC/EMV)