Built-In Module-Line Dual/Quad Cooktops

Part # 4532415 Rev 3 (8/19/14)

Page 17

Models: MO DU 14000/ 20000 MO QU 21000/ 24000/ 28000

4.4

Control Unit and Operation Unit (Power Switches)

4.4.1

Location

Distance of the control unit from the coil carrier sheet: MAX 800mm / 31.5”.
Distance of the control unit from the operation units (power switches): MAX 800mm / 31.5”.
 Keep the Service Interface window on the control unit accessible for service.
 Ensure the equipment and cable connections are accessible for maintenance and service.

4.4.2

Ventilation

 It is possible to install the induction unit near heat-producing or steam-producing equipment such as an

oven or a fryer. However, use an external fan to pull hot air, greasy fume, and moisture away from the
induction unit.

 The maximum operating temperature for the induction unit must not exceed 104F (40C).

3.98”

(101 mm)

3.98”

(101 mm)

6.22”

(158 mm)

14.17”

(360 mm)

23.62” (600 mm)

23.62” (600 mm)

air
supply

mains connection
field 1

coil connection
field 2

mains connection
field 2

coil connection
field 1

CAN/BUS

6.02” (153 mm)

6.81” (173 mm)

1.57” (40 mm)

0.91” (23 mm)

1.57” (40 mm)

2.09”
(53 mm)

5.16”

(131 mm)

min 1.57” (40 mm)

min 5” (127mm)

air exhaust

clearance

cable bend

clearance